Answers
Frequently asked questions
No email required. If a question you have isn't answered here, send it to us and we'll add it.
Technology
- What is EIC's liquid piston platform?
- EIC's platform is a near-isothermal gas compression and expansion system built around a liquid piston. Conventional compressors heat gas as they squeeze it, and holding onto that heat long enough to recover it is impractical in a storage system. The platform uses a liquid piston to carry the heat away as compression happens, so the gas stays close to a constant temperature. Keeping compression near-isothermal means energy is not spent fighting the pressure rise that heating causes, which is why the same platform can improve long-duration storage, industrial gas compression, CO₂ liquefaction and industrial cooling.
- What does 'isothermal compression' mean, in plain terms?
- Compressing a gas heats it up. That is why a bicycle pump gets warm. In a conventional (adiabatic) compressor that heat stays in the gas, and in principle you could recover it along with the pressure — but in practice it leaks away from the storage vessel over hours and days, taking the stored energy with it. Isothermal compression means compressing the gas while holding its temperature roughly constant, so energy is never spent raising the temperature in the first place. It is the theoretically most efficient way to compress a gas; the engineering challenge has always been achieving it at industrial scale, which is what EIC's liquid piston is designed to solve.
- How much less energy does this use than conventional compression?
- Our modeling shows a 20–30% reduction in energy consumption against conventional compression, depending on the gas, the pressure and the flow rate. Separately, published work has demonstrated a 19% efficiency gain for liquid piston compression over traditional gas compression, with round-trip efficiencies reaching 70%.
- Why does the liquid piston design matter?
- Using a liquid rather than a solid piston removes most of the mechanical complexity of a conventional compressor, and with it two standing losses: the sliding friction a mechanical piston needs in order to seal, and the gas that blows by past that sealing surface. EIC's design has approximately 90% fewer moving parts, which also reduces maintenance, extends service intervals and improves plant uptime — a significant factor in total cost of ownership for continuously operating industrial equipment.
- If heat leaving the system is a loss, why is removing it more efficient?
- Because of where the system boundary sits. So long as heat can move back into the process at the rate needed to hold temperature steady, the thermodynamic system is the compression vessel, the storage vessel and the atmosphere together — and the heat has not left that system at all. The atmosphere acts as an infinite heat sink during compression and an infinite heat source during expansion. Adiabatic compression retains the heat in the gas instead, which sounds better until you notice that heat leaks out of the storage vessel over hours and days, and the stored energy goes with it.
- Why use a liquid piston rather than a mechanical one?
- Four reasons, all of them about moving heat. First, geometry: heat transfer favors a long thin tube with maximum wall area per unit of gas, and a mechanical piston is realistically limited to single-digit length-to-diameter ratios while a liquid column is not. Second, speed: a liquid piston can advance far more slowly than a mechanical piston cycling through short travel, and its speed can be varied mid-cycle by controlling the pump delivery rate. Third, conformality: because liquid takes the shape of its vessel, the chamber cross-section can vary along its length to induce turbulence that improves heat transfer. Fourth, the liquid itself provides an additional heat transfer path from the gas interface out through the tube walls.
- Is pumping a liquid really more efficient than compressing a gas?
- Yes, and it is one of the less obvious advantages of the approach. Raising the pressure of a liquid in a pump is inherently more efficient than raising the pressure of a gas in a conventional compressor. Liquid's higher density means more of the motor's work is imparted to the fluid, and sealing a liquid is an easier engineering task than sealing a gas.
- Does the gas dissolve into the liquid?
- It can, and this is the main limitation of a liquid piston. How much gas dissolves depends on temperature, pressure and how miscible the two fluids are. There are established methods to mitigate it, but it is a genuine design constraint rather than a footnote, and it is where any serious engineering assessment of the approach should start.
- Is liquid piston technology new?
- No. It dates to at least 1906 and was used in some Stirling cycle applications, though it is not commonly found today. The current resurgence of interest is driven by its application to compressed air energy storage — one of the few long-duration storage approaches considered viable at genuinely large scale, and itself in use since the early twentieth century. Two compressed air storage plants have operated for many years, so the basic principles and their effectiveness are well understood.
- What efficiency gains has liquid piston compression actually demonstrated?
- Published work has demonstrated a 19% efficiency gain for liquid piston compression over traditional gas compression, and showed round-trip efficiencies increasing to 70% — removing one of the long-standing constraints on large-scale deployment. Full references are listed on our technology page.
- What is the system made of, and is it safe?
- Essentially air and water in a closed loop, operating in largely steel componentry. Unlike electrochemical storage it uses minimal rare or environmentally damaging materials: there are no toxic materials and no risk of thermal runaway, and degradation is minimal compared with batteries. We expect service life at least twice that of batteries.
- Does this only work with air?
- No. The compression technology applies to natural gas, hydrogen, biomass-derived fuel gases, carbon dioxide, oxygen and others, with applications in decarbonization, energy backup, buffering and pipeline injection. Air is simply the most practical medium when the objective is energy storage.
Energy storage
- What is xLDES, and how is it different from LDES?
- LDES stands for Long Duration Energy Storage — storage that can discharge for many hours, typically 8 to 100+ hours, rather than the one to four hours a lithium-ion battery usually provides. EIC uses xLDES (eXtra Long Duration Energy Storage) for storage that extends further still, into multi-day and seasonal durations. The distinction matters because renewable generation gaps are often measured in days, not hours, and battery chemistry becomes prohibitively expensive at those durations.
- How does the platform store energy?
- Surplus electricity — typically from solar or wind that would otherwise be curtailed — is used to compress air. The compressed air is stored, often in subsurface reservoirs for large-scale duty. When power is needed, the air is expanded back through the platform to generate electricity. Because both the compression and expansion steps run near-isothermally, far more of the original energy survives the round trip than in a conventional compressed-air system.
- Why does isothermal compression matter specifically for long duration storage?
- Because in an adiabatic system, the length of time you can usefully store energy is limited by how long you can hold onto heat. Once that heat escapes the storage vessel it cannot be recovered quickly, so the energy available on discharge falls the longer you wait. Your alternatives are storing low-grade heat, which is difficult over long periods, or reheating by burning fuel, which defeats the purpose of storing renewable energy. Near-isothermal compression removes that constraint, which is what makes multi-day storage practical.
- How is this different from other compressed air storage?
- Every version of compressed air storage has to answer the same question — what happens to the heat of compression. Diabatic CAES, the original 1978-era approach, lets the heat dissipate and burns fuel on discharge to offset the cooling of expansion; it works but is inefficient and carbon-intensive. Adiabatic or advanced CAES, used by companies such as Hydrostor and Energy Dome, captures that heat in a thermal store and re-uses it — better, but storing low-grade heat for long periods is costly and difficult, so the thermal store itself becomes the duration barrier. EIC compresses near-isothermally, so the heat never concentrates: it moves into the atmosphere as it forms and is drawn back during expansion. There is no thermal store to build or lose.
Commercial
- Can green energy reach cost parity with fossil generation using this approach?
- That is EIC's stated goal: to enable green energy at or below the cost of today's fossil-fired alternatives. The economic argument is that intermittent renewables are already cost-competitive to generate but expensive to make continuously available. By making the storage round trip substantially more efficient, EIC aims to deliver firm, 24/7 renewable power at a cost competitive with natural gas generation.
- Does EIC build and operate plants?
- No. EIC runs an asset-light licensing model. It designs, licenses, markets and supports liquid piston platform applications, while industry partners — OEM integrators, equipment manufacturers and EPC firms — build, manufacture and operate the resulting plants. EIC provides standardized designs, precertified components and design-to-operations software, earning revenue through licensing and software subscriptions rather than plant ownership.
- Who is the technology for?
- Two broad groups. First, energy producers and distributors: solar and wind generators, thermal plant operators, and grid operators facing congestion. Second, high energy density industrial users: AI data centers, large HVAC operators, oil and gas, cement and other process industries where compression and cooling represent a large share of the energy bill.
- Which industries does EIC serve?
- Thirteen, in two groups. Energy producers and distributors: electrical generation and transmission, natural gas extraction, waste-to-energy gas producers, natural gas transport, data centers and e-fuels. High energy density industrial users: large load behind-the-meter generators, large cooling loads, chemical production, hydrogen producers and users, cement, steel and carbon dioxide. What they share is gas that has to be compressed, stored or cooled at scale.
- Who are EIC's typical customers in each industry?
- Electrical generation and transmission: utilities, IPPs, RTOs, data centers, nuclear and geothermal. Large load behind-the-meter generators: data centers, mines and microgrids. Natural gas extraction: upstream natural gas producers. Waste-to-energy gas producers: process designers and biogas producers. Natural gas transport: liquefaction process designers and pipeline operators. Data centers: developers, EPCs, builders and power designers. E-fuels: process designers, syngas and alternative fuel plants. Large cooling loads: food storage and data centers. Chemical production: industrial gas producers and process plants. Hydrogen producers and users: steel, mobility, ammonia and fertilizer. Cement: cement plants. Steel: steel plants, including green steel. Carbon dioxide: carbon sequestration plants and carbon resale operations.
- What does the storage actually cost?
- We model total capex as low as $25 per kilowatt-hour of energy storage, against roughly $150 per kilowatt-hour for lithium-ion with about half the service life. This is capex per unit of storage capacity, not levelized cost of energy — the two are related but not interchangeable. The economics work because storage capacity is very cheap while power conversion equipment is not, so spreading the conversion cost across many hours of cheap storage lowers the cost per unit of delivered energy. The advantage therefore grows with duration rather than shrinking.
Deployment
- Does deploying this technology require rebuilding an existing plant?
- Not typically. The platform is designed to integrate with commercially available Balance of Plant (BOP) systems — the pumps, heat exchangers, controls and other supporting equipment that surround the core process — so that customers can adopt it with minimal disruption to existing operations.
- What is 'Balance of Plant' (BOP)?
- Balance of Plant refers to everything in a facility other than the primary equipment: pumps, piping, heat exchangers, electrical systems, instrumentation and controls. Using standard, commercially available BOP components rather than custom ones lowers cost, shortens procurement lead times and reduces project risk.
- Where is the compressed air actually stored?
- Underground, in naturally occurring formations. Depleted natural gas fields are the strongest candidate: the geology is already mapped by the previous operator, the integrity is proven, and some infrastructure can be re-purposed. Aquifers and other porous rock formations also work, and solution-mined salt beds are common though not available everywhere. Access cost is driven by depth, permeability and formation shape. Because these volumes occur naturally, the marginal cost of the storage itself approaches zero — which is what makes long duration affordable.
Company
- Where is Energy Internet Corporation based?
- EIC is headquartered in Phoenix, Arizona, with an R&D center in Bangalore, India, and offices in Sydney, Australia and Dubai, United Arab Emirates.
Didn't find your question?
Send it over — we answer directly, and good questions get added to this page.
Ask us